Lead acid battery charger: SRC-A100-12 |
|
|
|
| Model |
Input voltage |
Output voltage |
Output current |
Working Temp. |
Efficiency
|
Power |
| SRC-A100-12A |
100-240VAC |
13.8VDC |
5.0A |
0~+50º C |
83% |
75W |
| SRC-A100-12B |
100-240VAC |
13.8VDC |
4.8A |
0~+50º C |
83% |
75W |
| SRC-A100-12C |
100-240VAC |
13.8VDC |
4.5A |
0~+50º C |
83% |
75W |
| SRC-A100-12D |
100-240VAC |
13.8VDC |
4.2A |
0~+50º C |
83% |
75W |
| SRC-A100-12E |
100-240VAC |
13.8VDC |
4.0A |
0~+50º C |
83% |
75W |
| SRC-A100-12F |
100-240VAC |
13.8VDC |
3.5A |
0~+50º C |
83% |
75W |
Characteristics of 75W Lead Acid battery charger:
- Criterion: AC 100V~240V; Pressure Input: DC 125V~370V
- Input frequency: 47~63 Hz; Inrush Current: Max. 50A @ 230V Cold Start
- Short circuit protection: Long-term/Auto restart
- Overload protection: 110%~150%Power rating
- Withstand voltage: Input to Output 3.0KV/60s@3mA
- Size: 190×100×60(mm) Auto ColdOperating temp: 0~50°C@100%,-10°C@80%, 60°C@60%
- Energy standard: CEC, Energy Star and EU requirements
- Safety standard: EN60335,UL1310
- EMC Standard: EN55022 class B,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
- Approvals: CE,cUL, Rohs compliance
|